DYNAMICS AND CONTROL¶
Reconfiguring automatic transmission-6 (Aisin)¶
Block 02 → Long coding:
Byte 00 – Bits 00-23 – 000348 or enter another value (000852)
→ Apply
There are blocks with seven-digit encoding, for example: “0101000”, accordingly we change the first 7 characters in it from “0101000” to “0000008”.
What can be changed in this automatic transmission:
- 0000328 - factory coding for Škoda Rapid and some VW models
— 0000072 — factory coding Škoda Octavia A5FL
— 0000008 — encoding Audi A3, Škoda Octavia A5, VW Touran (before MY 2005) - 0008201 - Audi TT coding
- 0008264 - encoding Audi A3, VW Jetta
- 0008520 - VW Tiguan encoding - alternative encoding
2015-2016 block 09G 927 749xx (six-digit coding):
— 000348 – Stock
from model year 2016, block 09G 927 749xx, and from 2017 there is 09G 927 158 AL (already 20-byte encoding).
The most common and only coding for Octavia, Rapid and Polo sedan models: – 010100000C000000000000000000000000000000.
Other encoding options for such control units are also possible:
— 010200000C000000000000000000000000000000 — for 1.4 TFSI and 1.8 TFSI engines
— 010500000C000000000000000000000000000000 — for 1.6 CPDA engines.
Accordingly, with a 20-byte encoding, 010100000C0 ... until the end of zeros, change the first 7 digits - for example, to 00000080C ... until the end of zeros (Audi A3) - save!
Accordingly, with a 20-byte encoding, 010100000C0 ... until the end of zeros, change the first 7 digits - for example, to 00000080C ... until the end of zeros (Audi A3) - save!
Gas pedal recoding (reduced response to pressing)¶
Block 01 → Long coding:
Byte 00 – Bits 0-2 – select value 02 – execute. * not recommended for cars with cruise control - there will be cruise glitches
→ Apply
Changing the RAPID power steering settings (driving profile setting)¶
Block 44 → Long coding:
Byte 00 – Bit 7: Activate. The value changes from 00 to 80.
→ Apply
Block 44 → Adaptation
Characteristic curve of steering assistance → select the desired value (Driving profile selection button, Comfort, Automatic, Dynamic, Default)
→ Apply
*preferably value – Dynamic
Driving Profile switchover → select the desired value, direct...) → save.
*preferably value – Direct
→ Apply
Activating the TSC function¶
Side-steer compensation, compensation for torque differences on the drive wheels during hard acceleration - only for 1.4TSI
Block 44 → Long coding:
Byte 00 – Bit 2-3: Activate. The byte value changes from 00 to 04
→ Apply
Deactivating the start-stop function¶
Block 19 → Adaptation:
EM_start_stop_requirement_ambient_temperature:
- Minimum_temperature → -50.0 °C change value to 50.
Or by voltage:
- Start Stop voltage limit → 7.6V change to 12.1V